Products
We offer...
Vibration speed measuring range:
1–12,7; 1–25,4; 1–50,8; 1–76,2 mm/s
Frequency range: 3-1000 Hz
EX-rating - 0ExiaIICT4X
IP - IP67
Temperature range: -40 to +120 0С
Read more...
1–12,7; 1–25,4; 1–50,8; 1–76,2 mm/s
Frequency range: 3-1000 Hz
EX-rating - 0ExiaIICT4X
IP - IP67
Temperature range: -40 to +120 0С
Vibration acceleration measuring range:
490 mm/s2
Frequency range: 0,5 Hz... 10 kHz
EX-rating - 0ExiaIICT4X
IP - IP68
Temperature range: -54 to +121 0С
Read more...
490 mm/s2
Frequency range: 0,5 Hz... 10 kHz
EX-rating - 0ExiaIICT4X
IP - IP68
Temperature range: -54 to +121 0С
Vibration acceleration measuring:
range - 50g
shock pulses dBc, dBm - 0-100dB
temperature: -40 to +120 0С
Frequency range: 3 to 20000 Hz
EX-rating - 0ExiaIICT4X
IP - IP67
Temperature range: -56 to +125 0С
Read more...
range - 50g
shock pulses dBc, dBm - 0-100dB
temperature: -40 to +120 0С
Frequency range: 3 to 20000 Hz
EX-rating - 0ExiaIICT4X
IP - IP67
Temperature range: -56 to +125 0С
Measuring and computing complex SANPO for monitoring, diagnostics and emergency shut down of dynamic equipment is a unique design of “Komdiagnostika” which meets the requirements of API670 standard (American Petroleum Institute, Equipment protection systems).
Read more...
SP/P power supply module provides control and redundancy of SANPO supply circuits.
To achieve a high redundancy level, it is possible to connect two SP/P modules to SP/RACK crate, and one or two independent external power supplies «+24V» can be connected to SP/P module..
Read more...
To achieve a high redundancy level, it is possible to connect two SP/P modules to SP/RACK crate, and one or two independent external power supplies «+24V» can be connected to SP/P module..
SP/A Interface module is designed for initial configuration of measuring and computing complex, its diagnostics and creation of interface with upper level of vibration diagnostics system via two Ethernet.
Read more...
SP/S module is designed for analysis of the measuring modules OK signals, for control of «FAULT» relay which tells about measuring and computing complex fault, and for provision of discrete outputs for activation of such functions as alarm clearing, alarm bypass, special alarm bypass, multiplication of setpoints.
Read more...
Vibration protection and vibration diagnostics SP/V4 module provides voltage or current measurement from the sensors in four measuring channels as well as has current outputs of slowly varying 4-20 mА signals and buffer analog outputs for control. Four relays (RELAY) of SP/V4 module are programmed for special alarm conditions for one or several channels.
Read more...
Temperature control module SP/T6 is a 6-channel module which supports inputs for connection of thermocouples and resistant thermometers as well as 6 current outputs of slowly varying 4-20mA signal value DA-converter.
Four relay (RELAY) SP/T6 modules are programmed for special alarm setpoints for one or several channels.
Read more...
Four relay (RELAY) SP/T6 modules are programmed for special alarm setpoints for one or several channels.
The module has 8 comprehensive channels for analog input of unified voltage and current signals and 8 channels for analog output of current signals. Comprehensive SP/IO8 module can be applied for extending the number of channels of SP/V4 and SP/T6 modules by including more than one module into one protection contour.
Read more...
The unit is designed to measure r.m.s. value of voltage and alternative current, voltage and direct current of positive and negative polarity, as well as to form various electric signals in data acquisition and control high-performance systems.
Read more...
The module is designed to measure output voltage of the external source or of ICP-sensor in one or several measuring channels. Maximum number of measuring channels is four.
Read more...
The module is designed to measure output voltage of ICP-sensor in one or several measuring channels. Maximum number of measuring channels is eight.
Read more...
The module is designed to measure direct current in several measuring channels – from one to sixteen? Depending on the number of installed KDS27I20 transducers (up to eight), each of the transducers is, in its turn. a two-channel direct current measuring device.
Read more...
VIB-8 devices are designed to measure and transduce AC voltage output signals from the primary vibration transducers (vibration speed and vibration acceleration).
Read more...
Metal hose with 2S-shape lock, round, springy, high flexible, non-hermetic. The hose is mostly applied for mechanical protection of electric wiring (cables), tubes etc.
Read more...
"Komdiagnostika" LLC is accredited to provide test and calibration services of vibroacoustic measuring devices (vibration meters and vibration transducers).
Read more...
The way we work...


We get your request for equipment or services. At this stage, all technical issues are being settled.


We conclude equipment supply contract or service contract. At this stage, we provide the cost of equipment or services.


You proceed with the payment.

We supply the equipment (provide services on test or calibration of measuring devices).
How you can contact us...
"Komdiagnostika" (Moscow)
![]() |
73, Vera Voloshyna st., Mytishchi, Moscow region, The Russian Federation, 141014 |
![]() |
+7 (495) 926-95-31 |
![]() |
order@komdiagnostika.ru |
![]() |
General Director – Anton Melikhov |
loading map...