OUR COMPANY IS THE MANUFACTURER OF A COMPREHENSIVE MONITORING AND DIAGNOSTICS SYSTEM КD2210 FOR EVALUATION OF THE TECHNICAL CONDITION OF PUMP AND COMPRESSOR EQUIPMENT

SP/V4 – 4-channel vibration protection and vibration diagnostics module

SP-V4

Vibration protection and vibration diagnostics SP/V4 module provides voltage or current measurement from the sensors in four measuring channels as well as has current outputs of slowly varying 4-20 mА signals and buffer analog outputs for control.

SP/V4 provides power supply for the sensors and protection from short circuit, supports various sensor connection schemes, at the same time providing control of current consumption and power supply voltage of the sensor.

To provide the function of phase marker input signal, any SP/V4 channel supports the sensor connection scheme according to NAMUR standard, thus executing control of open circuit, short circuit and position of the sensor output signal within the requested range.

Four relays (RELAY) of SP/V4 module are programmed for special alarm conditions for one or several channels. Alarms can be programmed on operation with or without fixation.

 

SP/V4 specification:

 №  Feature   Measuring units  Value  
1.  Number of multifunctional measuring channels from the sensors   -  4
2.  Full range of sensor supply current from the module stabilizer circuit  mA from -40,2 to +40,5
3.  Current supply operating range for the sensors:    
      - for positive voltage of the sensor current supply  mA  from 2 to 30
      - for negative voltage of the sensor current supply  mA  from -30 to -2
4.  Loaded power supply (30 mA):    
      - for positive voltage of the sensor current supply  V  from 21 to 24
      - for negative voltage of the sensor current supply V  from -24 to -21
5.  ADC capacity of the sensors measuring channel   - 24
6.  Voltage measuring range of the broad band signal:    
      - for positive voltage of the sensor current supply V  from -1 to +21 
      - for negative voltage of the sensor current supply V  from -21 to 1 
7.  Input current measuring range «4-20 mA»  mA  from 0,1 to 24
8.  Differential input (inputs A, B) common-mode signal measuring range with respect to the common wire (input G)    
      - for positive voltage of the sensor current supply  V   from -1 to +21
      - for negative voltage of the sensor current supply  V  from -21 to 1
9.  Full dynamic transduction range of input broad band signal, min    dB  100
10.  A and B inputs input resistance with regard to the common wire   mOhm  2,0
11.  Signal bandwidth  Hz  0 - 50000 (with no program filters)
12.  Basic reduced measuring error of DC voltage (signal frequency is 100 Hz) for input broadband channel  %  ±0,2
13.  Basic reduced measuring error of AC voltage (signal frequency is 100 Hz) for input broadband channel  %  ±0,2
14.  Basic reduced measuring error of input DC «4-20 mА»  %  ±0,2
15.  Relative measuring error of AC frequency for input broadband channel  %  ±0,01
16.  Number of 4-20 mА outputs of slowly varying signal  -  4
17.  Output current measuring range of slowly varying signal  mA  from 2 to 24
18.  4-20 mА output load maximum resistance of slowly varying signal value   Ohm  900
19.  Capacity of 4-20mA output DA converter   -  16
20.  Number of independent relay outputs    -  4
21.  SP/V4 response time (from signal input to relay output), max  ms  100
22.  Power consumption, max  W  7
23.  PHY of data transmission to other modules in a crate via maid data transmission interface   -  100 Mbit/s
24.  Maximum number of modules in a crate with which SP/V4 can simultaneously support main data processing interface   -  6