VTEM skitter

EQUIPMENT

OUR COMPANY IS THE MANUFACTURER OF A COMPREHENSIVE MONITORING AND DIAGNOSTICS SYSTEM КD2210 FOR EVALUATION OF THE TECHNICAL CONDITION OF PUMP AND COMPRESSOR EQUIPMENT

Measuring module KDM24

KDM24-11-11-15Measuring module KDM24 is a component of a measuring unit KDR and is designed to measure external source output voltage or ICP-sensor output voltage in one or several measuring channels. Maximum number of measuring channels if four.

The module serves for applications which require high quality of digitalization of variable signal with high spectral accuracy of transformation, wide dynamic range and high signal-to-noise ratio. Four module channels are strictly parallel, independent, with no commutation delay between each other.

KDM24 technical specifications are proved by the Certificate of measuring device type approval RU.C.34.004.А № 52606, issued by the Federal technical regulation and metrology agency, Certificate of compliance № РОСС RU.ME79.H00188 and Declaration of conformity № ТС RU Д-RU.ME79.B.00027, registered by electric equipment certification body «Electroprivod», registration number РОСС.RU.0001.11ME79.

 

 

Main technical specifications of KDM24:

 No. Specification  Meas.unit Value 
1.  Number of measuring channels  -
2.  DC voltage measuring range (positive and negative polarity) in «Differential input» mode  V From 10-5 to 10
(subranges 10 В; 2 В)
3.  DC voltage RMS value measuring range:    
3.1.  – mode «Differential input» (with absolute momentary value of the measured voltage not exceeding the end value of measurements subrange)  V From 10-5 to 7,07
(subranges 10 В; 2 В) 
3.2.  – mode «ICP sensor» (for input voltage with DC component equal to + 10 В and changes of momentary value within + 1 to + 19 В in subrange 5 В, within + 8 to + 12 В in subrange 1 В)  V From 10-5 to 5
(subranges 5 В; 1 В)
4.  Limits of admissible main reduced (to the range end value) measuring error of DC voltage in «Differential input» mode  % ±0,05 
5.  Limits of admissible main reduced (to the range end value) measuring error of AC voltage RMS value:    
5.1.  – in «Differential input» mode  % ±(0,05 – 2,0)
5.2.  – in «ICP sensor» mode  % ±(0,1 – 4,0)
 6.  Common-mode rejection factor in «Differential input» mode for the noise, which is a DC voltage, and for the noise, which is an AC voltage with frequency of 50 Hz, no less than dB 77
7.  Jamming rate in «Differential input» mode for the noise, which is a DC voltage, and for the noise, which is an AC voltage with frequency of 50 Hz, no less than dB 75
8.  Input impedance of measuring inputs in «Differential input» mode in condition KDR ВКЛ, no less than Мohm 10
9.  Admissible overload between the contacts in each pair «Xi» and «Yi», «Xi» and «AGND», «Yi» and «AGND» (i – number of measuring channel in «Differential input») mode during 1 min  V  ±20
10.  Overall dimensions, no more than mm  26?130?155
11.  Weight, no more than kg 0,15